    Condensate Water Recovery Device

    Steam heating system includes of steam heating system and condensated water recovery system. Traditional condensated water recovery system is that the condensated water is discharged from the heating equipment, through the steam trap enter the condensated water tank, then through the water pump to delivery to the thermal deaerator, mixed with soft water to remove oxygen, through water pump to the boiler. For this open system, it will be flashing when the condensated water enter open water tank, which the flash steam enter the atmosphere to cause the condensated water loss, aslo the flash steam take away the condensated heat to low down the condensated water temperature. Therefore, open condensated water recovery system not only cause the heat and condensated water loss, but aslo cause the hot pollution for the surroundings. To solve this problem, our company research and develop the closed condensated water recovery device.


    Principle:
    During the system operation, condensated water is discharged from the heating equipment, through the steam trap enter the condensated water recovery device. Consenseated water recovery device is include of flash tank, dirt separator, the fast discharged device for condensated water, pressure balance device, cavitation remover, water storage tank, liquid level transmitter sensor etc.

    The high temperature condensated water enter the flash tank to seperate the steam and water, the water throught the fast discharge device to flow into the water storage tank that caused the second time steam through the ejectordevice into the outlet pipeline for water pump so that the flash steam can recovery closed. In the flash tank, steam and water are discharged constantly so that the pressure in the tank is still lower than the condensated water discharging port of heating device that make sure that although backpressure of return water is very low which can enter smoothly. In order to make the condensated water flows into water storage tank fast, there is a pressure balance device in the tank. Normally, the working pressure is set under 0.1MPa, we choose the working pressure as backpressure of return water to make sure the tank keep sealed, and not touch with the atmosphere.

    The steam and liquid in tank, under the adjusting effect of pressure balance device that the certain pressure is formed on the liquid surface. Through the cavitation remover to ensure the return water will not be cavitation.


    Features:
    1. Cavitation prevention
    2. Energy saving and environment protection
    3. High automatic program
    4. Small size
    5. Simple structure
    6. Flexible installation


    Technical parameter:

    Model

    Flow QTY m3/h

    Water inlet pipe D1(mm)

    Drainage pipe D2(mm)

    Pressure tube D3(mm)

    BTLN-1

    1

    65

    50

    50

    BTLN-2

    2

    65

    50

    50

    BTLN-4

    4

    80

    65

    65

    BTLN-6

    6

    80

    65

    80

    BTLN-8

    8

    80

    65

    80

    BTLN-10

    10

    100

    80

    80

    BTLN-20

    20

    125

    100

    100

    BTLN-35

    35

    150

    125

    125

    BTLN-50

    50

    200

    150

    150

    BTLN-100

    100

    250

    200

    200


    Product show:

     image007.jpg

    image003(001).jpg image005(001).jpg


    Following is the Condensate Water Recovery pump units

     image011(001).jpg

     image015(001).jpg


Send your message to this supplier
To:  

Nanjing Beite AC Equipment Co.,Ltd

* Content:  

For better quotations, include:

- A self introduction

- Special requests, if any

Quantity:  

  
You May Like
Not exactly what you want? One request, multiple quotations Get Quotations Now >>
Related Searches :